pvlib.pvsystem.Array.get_cell_temperature#
- Array.get_cell_temperature(poa_global, temp_air, wind_speed, model, effective_irradiance=None)[source]#
Determine cell temperature using the method specified by
model.- Parameters
poa_global (numeric) – Total incident irradiance [W/m^2]
temp_air (numeric) – Ambient dry bulb temperature [C]
wind_speed (numeric) – Wind speed [m/s]
model (str) – Supported models include
'sapm','pvsyst','faiman','fuentes', and'noct_sam'effective_irradiance (numeric, optional) – The irradiance that is converted to photocurrent in W/m^2. Only used for some models.
- Returns
numeric – Values in degrees C.
See also
pvlib.temperature.sapm_cell,pvlib.temperature.pvsyst_cell,pvlib.temperature.faiman,pvlib.temperature.fuentes,pvlib.temperature.noct_samNotes
Some temperature models have requirements for the input types; see the documentation of the underlying model function for details.